GROUND IMPROVEMENTS FOR BUILDING PROJECTS
By Dan Martel, P.E.
Ground improvements are just like they sound strategies that involve installing aggregate and/or cementitious materials like concrete to improve the engineering properties of the ground below a building. These strategies are used as alternatives to traditional deep foundations like steel piles. They are used when the bearing strata is not suitable for foundation loads, like with organic or compressible materials, or unsuitable fill materials.
Common strategies include rammed aggregate pier and rigid inclusions formed with concrete or grout.
Team Engineering are the structural engineers for three recent projects utilizing ground improvements:
A 70-foot tall addition to house a film extruding machine
Geotechnical explorations found 10-foot deep “uncontrolled fill” across the entire building site – meaning the fille was placed by man for the purpose of filling volume including sand, roots, stumps, and demolished building materials like bricks and wood. Compared to structural fill, which is comprised of compactible materials with bearing capacity and intended to support loads. (Organics are unsuitable for bearing because they are compressible and decomposable, leading to high settlement.) The geotechnical engineer recommended ground improvements consisting of rigid inclusions, or helical piles, for foundation loads to bypass the unsuitable materials.
Helical Drilling designed and constructed concrete rigid inclusions for most of the foundations. In areas where undermining the existing building was a concern, and there was limited access to install elements and helical piles, ductile iron piles with pile caps were utilized. The ground improvements proved to be cheaper than removing 10 feet of soil and replacing them with suitable materials.
The portion of the building housing three extruders is 70-feet tall, which provide large wind load reactions on the column footings. The metal building design used a limited number of columns for equipment and forklift floor plan flexibility, so the wind and snow loads were concentrated to a small number of footings. The result was a footing design that needed to consider high downward, lateral, and uplift design loads.

Concrete Rigid Inclusion Boring machine. Concrete is pumped to top of casing.

Some concrete spoils should be expected

The finished extruder building

Rendering (Courtesy of Alessi Architecture)
Geotechnical explorations were performed very early in the process, so the owner and design team were well prepared to consider the challenging conditions in the design. The site contains 10-14 feet of peat and other organics 4-7 feet below surface. The geotechnical engineer found the conditions unsuitable for conventional spread footings and recommended “improved subgrade” as more cost-effective than piles.
Helical Drilling was engaged early to be the deep foundation design-building contractor. They concluded that rigid inclusions with concrete were the most economical ground improvement approach. Their design resulting in an improved ground that, for our foundation design perspective, behaved very much like a 4,000psf bearing capacity native soil. So we utilized perimeter and interior bearing wall strip footings, isolated footings as needed for posts, and a mat slab to support the elevator.

Rigidi inclusion equipment. Including the excavator fit with an auger bit to pre-drill holes for faster inclusion construction.

Ground improvement element production setup

Setting up for testing a rigid inclusion, including four tension piles that will counteract test element compression force
Indoor Sports Facility (Design in Progress)
The owner purchased the site aware of challenging geotechnical conditions, including marine sand, marine silt, and marine clay. They engaged a geotechnical engineer initially to make recommendations for the site to accommodate loads from a building with large spans to accommodate indoor sports fields. Since marine clays can consolidate, they first recommended pre-loading the site with compacted sands and gravel so the consolidation could be controlled. This was necessary as a cost-effective way to reduce the number of ground improvement elements.

- What we’ve learned:
- Ground improvements are often considered a deep foundation strategy, including by the Massachusetts State Building Code. That means they are subject to the same design, testing, and special inspection requirements as steel piles, for example.
- Accommodates uniform bearing pressure far better than discrete loads such as warehouse rack legs.
- Ground improvements are great at both increasing bearing capacity and reducing consolidation/settlement.
- Systems are being implemented by specialty design-build contractors, installing proprietary solutions like from GeoPier. With specialty in-house geotechnical engineers.
- Concrete rigid conclusions have limited spoils because they are injected. Compared to micropiles, which can displace unsuitable material via slurry.
- Timber piles behave more like ground improvements than piles. Perhaps the original ground improvement strategy, we know the success using these historical in Back Bay Boston and Venice.
- One difference between piles and ground improvements: piles usually have connection for loads transfer to footings, while ground improvements have no connection
Ground improvement elements, like unimproved ground, typically do not have large lateral load capacities. Whereas piles often do have lateral capacity. We therefore need to utilize other methods, like passive earth pressure in line with footings, since friction below footings cannot necessarily be transferred well to improved ground.
More Articles From...
| This Category | Structural Design, Structural Engineering |
| This Author | Dan Martel, P.E. |